Specifications |
Bandwidth |
Fluke 190-504: 500 MHz
Fluke 190-204: 200 MHz
Fluke 190-202: 200 MHz
Fluke 190-104: 100 MHz
Fluke 190-102: 100 MHz
Fluke 190-062: 60 MHz |
Number of channels |
Fluke 190-504: 500 MHz: 4 channels
Fluke 190-204: 200 MHz: 4 channels
Fluke 190-202: 200 MHz: 2 channels
Fluke 190-104: 100 MHz: 4 channels
Fluke 190-102: 100 MHz: 2 channels
Fluke 190-062: 60 MHz: 2 channels |
Real-time sample rate |
Fluke 190-504: 5 GS/s
Fluke 190-204: 2.5 GS/s
Fluke 190-202: 2.5 GS/s
Fluke 190-104: 1.25 GS/s
Fluke 190-102: 1.25 GS/s
Fluke 190-062: 625 MS/s |
Inputs |
Fluke 190-X04: 4x BNC input for scope and meter measurements
Fluke 190-X02: 2x BNC input plus 1x DMM input |
Independently floating isolated inputs |
Up to 1000 V CAT III/600 V CAT IV between inputs, references and ground |
Timebase range |
1 ns/div to 4s/div (190-504, 500 MHz model)
2 ns/div to 4s/div (190-20X, 200 MHz models)
5 ns/div to 4s/div (190-10X, 100 MHz models)
10 ns/div to 4s/div (190-062, 60 MHz model) |
Input sensitivity |
2 mV-100 V/div plus variable attentuation |
Trigger types |
Connect-and-View™, Free Run, Single Shot, Edge, Delay, Dual Slope, Video, Video Line, Selectable pulse width, N-Cycle |
Trigger source |
Fluke 190-X02: 2x BNC input or external via DMM input
Fluke 190-X04: 4x BNC input |
Glitch capture |
8 ns |
Scope measurements |
Cursor: 7
Automatic: 30 |
Maximum record length |
ScopeRecord mode: 30,000 pts per input
Scope mode: 10,000 pts per input |
Persistence |
Digital persistence giving analog oscilloscope-like waveform decay |
Waveform compare |
Waveform reference with automatic Pass/Fail testing |
DMM Specifications (Two-Channel Models) |
Meter inputs
(also used as External Trigger Input for the Oscilloscope Mode) |
4 mm banana inputs, fully isolated from scope inputs and from scope ground |
Maximum resolution |
5000 counts |
Measurements |
Vdc, Vac rms, Vac+dc rms, Resistance, Continuity, Diode Test, Current (through clamp or shunt), Temperature ºC or ºF (using optional converter) |
Memory locations |
Screen + Setup: 30 Waveform memories plus 10 recording memories plus 9 screencopy memories. |
Display |
153 mm full color LCD with fast update rate |
Environmental Specifications |
Operating temperature |
0ºC to 40ºC Including Batteries
0ºC to 50ºC Excluding Batteries |
Storage temperature |
-20°C to +60°C |
Operating altitude |
Up to 2,000 m (6666 ft) for CAT IV 600 V/ CAT III 1,000 V
Up to 3,000 m (10,000 ft) for CAT III 600 V/ CAT II 1,000 V |
Safety Specifications |
Electrical safety |
1,000V CAT III/600V CAT IV (EN61010-1) |
Mechanical and General Specifications |
Size |
270 x 190 x 70 mm |
Weight |
2.2 kg |
Warranty |
Three-years on main instrument |
Li-Ion battery |
Fluke 190-XX2: BP290 (2400mAh)
Fluke 190-XX4: BP291 (4800mAh) |
|
|
|
|