OVERVIEW & SPECIFICATION
The Fluke 345 is more than an electric power meter. Combining the functions of a clamp meter, oscilloscope, data logger and digital power meter into one handy device, the Fluke 345 is ideal for working with variable frequency motor drives, high efficiency lighting and other loads using switching electronics.
- Setup and troubleshoot variable frequency drives and UPS systems – Verify correct operation by measuring key power quality parameters
- Harmonics measurements – Uncover harmonic issues that can damage or disrupt critical equipment
- Inrush capture – Check start-up current where spurious resets or nuisance circuit breaker tripping occurs
- Load studies – Verify electrical system capacity before adding loads
Display |
|
Color transmissive LCD 320 x 240 pixels (70 mm diagonal) with 2 level backlight |
|
|
Power supply |
|
|
Battery type 1.5 V Alkaline AA MN 1500 or IEC LR6 x 6 |
|
Battery life typically |
|
> 10 hours (backlight on full) |
|
> 12 hours (backlight reduced) |
|
Battery Eliminator BE345 |
Input |
110/230 V 50/60 Hz |
Output |
15 V dc, 300 mA |
|
Ambient conditions (For indoor use only) |
Reference conditions |
|
All accuracies stated at 23˚C ± 1˚C (73.4 °F ± 1.8 °F) |
|
Operating temperature |
|
0 °C to 50 °C (32 °F to 122 °F) |
|
Temperature coefficient of current |
|
Temperature coefficient of voltage |
|
Maximum relative humidity |
|
80 % for temperatures up to 31 °C (87 °F) decreasing linearly to 50 % relative humidity at 40 °C (104 °F) |
|
Maximum operating altitude |
|
Electrical safety |
Maximum safe working voltages |
|
Safety IEC 61010-1 600 V CAT IV double or reinforced insulation, pollution degree 2 |
|
|
|
Current measurement |
|
600 V ac rms or dc between uninsulated conductor and ground |
|
Voltage measurement |
|
600 V ac rms or dc between either input terminal and ground, or 825 V between energized phase voltages (delta power config.) |
|
EMC |
Emission |
|
IEC/EN 61326-1:1997 class A |
|
Immunity |
|
IEC/EN 61326-1:1997 Annex C Performance Criterion B |
|
Mechanical |
Dimensions (length x width x depth) |
|
300 mm x 98 mm x 52 mm (12 in x 3.75 in x 2 in) |
|
Weight including batteries |
|
Jaw opening |
|
Jaw capacity |
|
Cleaning |
|
The unit can be cleaned with an Isopropanol impregnated cloth. Do not use abrasives or other solvents. |
|
Electrical data |
All accuracies stated at 23 °C ± 1 °C (73.4 °F ± 1.8 °F). See Ambient conditions specifications for temperature coefficients. |
|
Current measurement (dc, dc rms, ac rms) |
Measuring range |
|
0 to 2000 A dc or 1400 ac rms |
|
Autorange facility |
|
Resolution |
|
10 mA in 40 A range |
|
100 mA in 400 A range |
|
1 A in 2000 A range |
|
Fluke-345
OVERVIEW & SPECIFICATION
The Fluke 345 is more than an electric power meter. Combining the functions of a clamp meter, oscilloscope, data logger and digital power meter into one handy device, the Fluke 345 is ideal for working with variable frequency motor drives, high efficiency lighting and other loads using switching electronics.
- Setup and troubleshoot variable frequency drives and UPS systems – Verify correct operation by measuring key power quality parameters
- Harmonics measurements – Uncover harmonic issues that can damage or disrupt critical equipment
- Inrush capture – Check start-up current where spurious resets or nuisance circuit breaker tripping occurs
- Load studies – Verify electrical system capacity before adding loads
Display |
|
Color transmissive LCD 320 x 240 pixels (70 mm diagonal) with 2 level backlight |
|
|
Power supply |
|
|
Battery type 1.5 V Alkaline AA MN 1500 or IEC LR6 x 6 |
|
Battery life typically |
|
> 10 hours (backlight on full) |
|
> 12 hours (backlight reduced) |
|
Battery Eliminator BE345 |
Input |
110/230 V 50/60 Hz |
Output |
15 V dc, 300 mA |
|
Ambient conditions (For indoor use only) |
Reference conditions |
|
All accuracies stated at 23˚C ± 1˚C (73.4 °F ± 1.8 °F) |
|
Operating temperature |
|
0 °C to 50 °C (32 °F to 122 °F) |
|
Temperature coefficient of current |
|
Temperature coefficient of voltage |
|
Maximum relative humidity |
|
80 % for temperatures up to 31 °C (87 °F) decreasing linearly to 50 % relative humidity at 40 °C (104 °F) |
|
Maximum operating altitude |
|
Electrical safety |
Maximum safe working voltages |
|
Safety IEC 61010-1 600 V CAT IV double or reinforced insulation, pollution degree 2 |
|
|
|
Current measurement |
|
600 V ac rms or dc between uninsulated conductor and ground |
|
Voltage measurement |
|
600 V ac rms or dc between either input terminal and ground, or 825 V between energized phase voltages (delta power config.) |
|
EMC |
Emission |
|
IEC/EN 61326-1:1997 class A |
|
Immunity |
|
IEC/EN 61326-1:1997 Annex C Performance Criterion B |
|
Mechanical |
Dimensions (length x width x depth) |
|
300 mm x 98 mm x 52 mm (12 in x 3.75 in x 2 in) |
|
Weight including batteries |
|
Jaw opening |
|
Jaw capacity |
|
Cleaning |
|
The unit can be cleaned with an Isopropanol impregnated cloth. Do not use abrasives or other solvents. |
|
Electrical data |
All accuracies stated at 23 °C ± 1 °C (73.4 °F ± 1.8 °F). See Ambient conditions specifications for temperature coefficients. |
|
Current measurement (dc, dc rms, ac rms) |
Measuring range |
|
0 to 2000 A dc or 1400 ac rms |
|
Autorange facility |
|
Resolution |
|
10 mA in 40 A range |
|
100 mA in 400 A range |
|
1 A in 2000 A range |
|