OVERVIEW & SPECIFICATION

Fluke-414D/419D/424D on your tool belt and reach beyond the common tape measure – up to 50 meters (165 ft). This professional-grade laser distance meter is fast and easy to use, improving accuracy and reducing measurement errors. You’ll save time and money at every step.
414D 419D 424D
Distance Measurement
Typical Measuring Tolerance[1] ± 2.0 mm [3] ± 1.0 mm [3]
Maximum Measuring Tolerance[2] ± 3.0 mm [3] ± 2.0 mm [3]
Range at Leica target plate GZM26 50 m / 165 ft 80 m / 260 ft 100 m / 330 ft
Typical Range[1] 40 m / 130 ft 80 m  / 260 ft 80 m / 260 ft
Range at unfavorable condition[4] 35 m / 115 ft 60 m / 195 ft 60 m / 195 ft
Smallest unit displayed 1 mm / 1/16 in 6 /30 / 60 mm
(10 / 50 / 100 m)
∅ laser point at distances 6 /30 / 60 mm
(10 / 50 / 100 m)
6 /30 / 60 mm
(10 / 50 / 100 m)
Tilt measurement
Measuring tolerance to laser beam[5] No No ± 0.2°
Measuring tolerance to housing[5] No No ± 0.2°
Range No No 360°
General
Laser class 2
Laser type 635 nm, <1 mW
Protection class IP40 IP54
Automatic laser off After 90 seconds
Automatic power off after 180 seconds
Battery life (2 x AAA) 1.5 V NEDA 24A/IEC LR03 Up to 3,000
measurements
Up to 5,000
measurements
Size (H X W X L) 116mm Length
53mm Width
33mm Depth
127mm Length
56mm Width
33mm Depth
127mm Length
56mm Width
33mm Depth
Weight (with batteries) 113 g 153 g 158 g
Temperature range: Storage Operation -25 °C to +70°C
(-13 °F to +158 °F)0 °C to +40 °C
(32 °F to +104 °F)
-25 °C to +70°C
(-13 °F to +158 °F)-10 °C to +50 °C
(14 °F to +122 °F)
Calibration cycle Not applicable Not applicable Tilt and compass
Maximum altitude 3000 m 3000 m 3000 m
Maximum relative humidity 85% at 20 °F to 120°F
(-7 °C to 50 °C)
85% at 20 °F to 120°F
(-7 °C to 50 °C)
85% at 20 °F to 120°F
(-7 °C to 50 °C)
Safety IEC Standard No. 61010-1:2001
EN60825-1:2007 (Class II)
EMC EN 55022:2010
EN 61000-4-3:2010
EN 61000-4-8:2010
[1] Applies for 100 % target reflectivity (white painted wall), low background illumination, 25 °C.
[2] Applies for 10 to 500 % target reflectivity, high background illumination, -10 °C to +50 °C.
[3] Tolerances apply from 0.05 m to 10 m with a confidence level of 95 %. The maximum tolerance may deteriorate to 0.1 mm/m between 10 m to 30 m and to 0.15 mm/m for distances above 30 m.
[4] Applies for 100 % target reflectivity, background illumination between 10’000 lux and 30’000 lux.
[5] After user calibration. Additional angle related deviation of ±0.01° per degree up to ±45° in each quadrant. Applies at room temperature. For the whole operating temperature range the maximum deviation increases by ±0.1°.


Fluke- 414D/419D/424D

OVERVIEW & SPECIFICATION

Fluke-414D/419D/424D on your tool belt and reach beyond the common tape measure – up to 50 meters (165 ft). This professional-grade laser distance meter is fast and easy to use, improving accuracy and reducing measurement errors. You’ll save time and money at every step.
414D 419D 424D
Distance Measurement
Typical Measuring Tolerance[1] ± 2.0 mm [3] ± 1.0 mm [3]
Maximum Measuring Tolerance[2] ± 3.0 mm [3] ± 2.0 mm [3]
Range at Leica target plate GZM26 50 m / 165 ft 80 m / 260 ft 100 m / 330 ft
Typical Range[1] 40 m / 130 ft 80 m  / 260 ft 80 m / 260 ft
Range at unfavorable condition[4] 35 m / 115 ft 60 m / 195 ft 60 m / 195 ft
Smallest unit displayed 1 mm / 1/16 in 6 /30 / 60 mm
(10 / 50 / 100 m)
∅ laser point at distances 6 /30 / 60 mm
(10 / 50 / 100 m)
6 /30 / 60 mm
(10 / 50 / 100 m)
Tilt measurement
Measuring tolerance to laser beam[5] No No ± 0.2°
Measuring tolerance to housing[5] No No ± 0.2°
Range No No 360°
General
Laser class 2
Laser type 635 nm, <1 mW
Protection class IP40 IP54
Automatic laser off After 90 seconds
Automatic power off after 180 seconds
Battery life (2 x AAA) 1.5 V NEDA 24A/IEC LR03 Up to 3,000
measurements
Up to 5,000
measurements
Size (H X W X L) 116mm Length
53mm Width
33mm Depth
127mm Length
56mm Width
33mm Depth
127mm Length
56mm Width
33mm Depth
Weight (with batteries) 113 g 153 g 158 g
Temperature range: Storage Operation -25 °C to +70°C
(-13 °F to +158 °F)0 °C to +40 °C
(32 °F to +104 °F)
-25 °C to +70°C
(-13 °F to +158 °F)-10 °C to +50 °C
(14 °F to +122 °F)
Calibration cycle Not applicable Not applicable Tilt and compass
Maximum altitude 3000 m 3000 m 3000 m
Maximum relative humidity 85% at 20 °F to 120°F
(-7 °C to 50 °C)
85% at 20 °F to 120°F
(-7 °C to 50 °C)
85% at 20 °F to 120°F
(-7 °C to 50 °C)
Safety IEC Standard No. 61010-1:2001
EN60825-1:2007 (Class II)
EMC EN 55022:2010
EN 61000-4-3:2010
EN 61000-4-8:2010
[1] Applies for 100 % target reflectivity (white painted wall), low background illumination, 25 °C.
[2] Applies for 10 to 500 % target reflectivity, high background illumination, -10 °C to +50 °C.
[3] Tolerances apply from 0.05 m to 10 m with a confidence level of 95 %. The maximum tolerance may deteriorate to 0.1 mm/m between 10 m to 30 m and to 0.15 mm/m for distances above 30 m.
[4] Applies for 100 % target reflectivity, background illumination between 10’000 lux and 30’000 lux.
[5] After user calibration. Additional angle related deviation of ±0.01° per degree up to ±45° in each quadrant. Applies at room temperature. For the whole operating temperature range the maximum deviation increases by ±0.1°.