OVERVIEW & SPECIFICATION

he Fluke 568 Ex Intrinsically Safe Infrared Thermometer is the one product you can use in Class I Div 1 and Div 2 or Zone 1 and 2 hazardous environments anywhere in the world. Whether you work in petroleum, chemical, oil and gas, or pharmaceutical environments, the 568 Ex allows you to carry the most trusted name in test tools into most Ex rated areas all around the globe.

Specifications
Infrared temperature range -40 °C to 800 °C
(-40 °F to 1472 °F)
Infrared accuracy < 0 °C (32 °F): ± (1.0 °C (± 2.0 °F) + 0.1°/1 °C or °F);
> 0 °C (32 °F):  ± 1 % or  ± 1.0 °C (± 2.0 °F), whichever is greater
Display resolution 0.1 °C / 0.1 °F
Infrared spectral response 8 µm to 14 µm
Infrared response time < 500 ms
Thermocouple type-k input temperature range -270 °C to 1372 °C (-454 °F to 2501 °F)
Thermocouple type-k input accuracy <-40 °C: ±(1 °C + 0.2 °/1 °C)
≥-40 °C: ±1 % or 1 °C, whichever is greater <-40 °F: ±(2 °F + 0.2 °/1 °F)
≥-40 °F: ±1 % or 2 °F, whichever is greater
D:S (distance to measurement spot size) 50:1
Laser sighting Single-point laser
Minimum spot size 19 mm (0.75 in)
Emissivity adjustment By built-in table of common materials or digitally adjustable from 0.10 to 1.00 by 0.01
Data storage 99 points
Hi/Low alarms Audible and two-color visual
Min/Max/Avg/Dif Yes
Display Dot matrix with function menus
Backlight Two levels, normal and extra bright for darker environments
Trigger lock Yes
Switchable celsius and fahrenheit Yes
Power 2 AAA/LR03 type-approved batteries (For a list of type-approved batteries, refer to Product Safety Instructions.)
Battery life 4 hours with laser and backlight on;
100 hours with laser and backlight off, at 100 % duty cycle
Operating temperature 0 °C to 50 °C (32 °F to 122 °F)
Storage temperature -20 °C to 60 °C (-40 °F to 140 °F)
Bead thermocouple type-k range -40 °C to 260 °C (-40 °F to 500 °F)
Bead thermocouple type-k accuracy ± 1.1 °C (2.0 °F) from 0 °C to 260 °C (32 °F to 500 °F),
typically within 1.1 °C (2.0 °F) from -40 °C to 0 °C (-40 °F to 32 °F)

 

Safety Certifications
Agency Safety Rating
ATEX/ IECEx
Zone 1 and 2
IECEx EPS 13.0006X
Ex ia IIC T4 Gb
0°C ≤ Ta ≤ 50°C
EPS 13 ATEX 1.525 X
II 2G Ex ia IIC T4 Gb
NEC-500 / NEC-505
Class I Division 1 and 2
Class I, Division 1, Groups ABCD T4
Class I, Division 2, Groups ABCD T4
Class I, Zone 1, AEx ia IIC T4
Ex ia IIC T4
0°C ≤ Ta ≤ 50°C
GOST
Zone 1 and 2
POCC DE.ГБ05.B
Ex ia IIC T4 Gb X
ОТ 0°C ДО +50°C
EPS 13 ATEX 1 525 X
II 2G Ex ia IIC T4 Gb
0°C ≤ Ta ≤ 50°C
PCEC
Zone 1 and 2
PCEC
Ex ia IIC T4 Gb
CE13.
EPS 13 ATEX 1 525 X
II 2G Ex ia IIC T4 Gb
0°C ≤ Ta ≤ 50°C
INMETRO
Zone 1 and 2
IEx 13.0122X
Ex ia IIC T4 Gb
EPS 13 ATEX 1 525 X
II 2G Ex ia IIC T4 Gb
0°C ≤ Ta ≤ 50°C


Fluke 568 Ex

OVERVIEW & SPECIFICATION

he Fluke 568 Ex Intrinsically Safe Infrared Thermometer is the one product you can use in Class I Div 1 and Div 2 or Zone 1 and 2 hazardous environments anywhere in the world. Whether you work in petroleum, chemical, oil and gas, or pharmaceutical environments, the 568 Ex allows you to carry the most trusted name in test tools into most Ex rated areas all around the globe.

Specifications
Infrared temperature range -40 °C to 800 °C
(-40 °F to 1472 °F)
Infrared accuracy < 0 °C (32 °F): ± (1.0 °C (± 2.0 °F) + 0.1°/1 °C or °F);
> 0 °C (32 °F):  ± 1 % or  ± 1.0 °C (± 2.0 °F), whichever is greater
Display resolution 0.1 °C / 0.1 °F
Infrared spectral response 8 µm to 14 µm
Infrared response time < 500 ms
Thermocouple type-k input temperature range -270 °C to 1372 °C (-454 °F to 2501 °F)
Thermocouple type-k input accuracy <-40 °C: ±(1 °C + 0.2 °/1 °C)
≥-40 °C: ±1 % or 1 °C, whichever is greater <-40 °F: ±(2 °F + 0.2 °/1 °F)
≥-40 °F: ±1 % or 2 °F, whichever is greater
D:S (distance to measurement spot size) 50:1
Laser sighting Single-point laser
Minimum spot size 19 mm (0.75 in)
Emissivity adjustment By built-in table of common materials or digitally adjustable from 0.10 to 1.00 by 0.01
Data storage 99 points
Hi/Low alarms Audible and two-color visual
Min/Max/Avg/Dif Yes
Display Dot matrix with function menus
Backlight Two levels, normal and extra bright for darker environments
Trigger lock Yes
Switchable celsius and fahrenheit Yes
Power 2 AAA/LR03 type-approved batteries (For a list of type-approved batteries, refer to Product Safety Instructions.)
Battery life 4 hours with laser and backlight on;
100 hours with laser and backlight off, at 100 % duty cycle
Operating temperature 0 °C to 50 °C (32 °F to 122 °F)
Storage temperature -20 °C to 60 °C (-40 °F to 140 °F)
Bead thermocouple type-k range -40 °C to 260 °C (-40 °F to 500 °F)
Bead thermocouple type-k accuracy ± 1.1 °C (2.0 °F) from 0 °C to 260 °C (32 °F to 500 °F),
typically within 1.1 °C (2.0 °F) from -40 °C to 0 °C (-40 °F to 32 °F)

 

Safety Certifications
Agency Safety Rating
ATEX/ IECEx
Zone 1 and 2
IECEx EPS 13.0006X
Ex ia IIC T4 Gb
0°C ≤ Ta ≤ 50°C
EPS 13 ATEX 1.525 X
II 2G Ex ia IIC T4 Gb
NEC-500 / NEC-505
Class I Division 1 and 2
Class I, Division 1, Groups ABCD T4
Class I, Division 2, Groups ABCD T4
Class I, Zone 1, AEx ia IIC T4
Ex ia IIC T4
0°C ≤ Ta ≤ 50°C
GOST
Zone 1 and 2
POCC DE.ГБ05.B
Ex ia IIC T4 Gb X
ОТ 0°C ДО +50°C
EPS 13 ATEX 1 525 X
II 2G Ex ia IIC T4 Gb
0°C ≤ Ta ≤ 50°C
PCEC
Zone 1 and 2
PCEC
Ex ia IIC T4 Gb
CE13.
EPS 13 ATEX 1 525 X
II 2G Ex ia IIC T4 Gb
0°C ≤ Ta ≤ 50°C
INMETRO
Zone 1 and 2
IEx 13.0122X
Ex ia IIC T4 Gb
EPS 13 ATEX 1 525 X
II 2G Ex ia IIC T4 Gb
0°C ≤ Ta ≤ 50°C