OVERVIEW & SPECIFICATION

The new Fluke 718Ex Intrinsically Safe Pressure Calibrator is a new, powerful intrinsically safe, self contained pressure calibrator for usage in Explosion endangered areas.

The Fluke 718Ex offers:

  • ATEX II 1G Ex ia IIC T4 Compliant.
  • Built-in pressure / vacuum hand pump, with fine adjust vernier and bleed valve.
  • 30, 100, and 300 psi ranges (2, 7, and 20 bar)
  • Pressure measurement to 0.05% of full span, using an internal pressure sensor.
  • Pressure measurement to 200 bar using any of eight intrinsically safe Fluke 700PEx Pressure Modules.
  • Wide range of selectable measurement units for pressure.
  • Current measurement with 0.02% accuracy and 0.001 mA resolution.
  • Pressure switch test function.
  • Min-Max Hold functions.
  • Compact size and weight.
  • Simple, push-button user interface.
  • Rugged and reliable, ideal for field use.
Measurement Accuracy
Pressure
Fluke 718Ex 30G
Range:  -830 mbar to 2 bar (internal sensor)
 Over pressure: 3x FS
Resolution:  0.0001 bar
Accuracy:  0.05% FS
Functions:  Zero, Min, Max, Hold, Damp
 Note: for use with non-corrosive gasses
Fluke 718Ex 100G
Range:  -830 mbar to 7 bar (internal sensor)
 Over pressure: 2x FS
Resolution:  0.001 bar
Accuracy:  0.05% FS
Functions:  Zero, Min, Max, Hold, Damp
 Note: for use with non-corrosive gasses
Fluke 718Ex 300G
Range:  -830 mbar to 20 bar (internal sensor)
 Over pressure: 375 psi, 25 bar
Resolution:  0.0001 bar
Accuracy:  0.05% FS
Functions:  Zero, Min, Max, Hold, Damp
 Note: for use with non-corrosive gasses
Fluke 718Ex series
 via pressure module connector
Range:  29 pressure modules, 2.5 mbar to 700 bar
 Over pressure per pressure module specs
Resolution:  Per pressure module specs
Accuracy:  To 0.025% of full span, per pressure module specs
Functions:  Zero, Min, Max, Hold, Damp
 Note: media compatibility per pressure module specs
Source Pressure, built in pump
Range:  -820 mbar to full scale
Note:  Supported Pressure Units PSI, in. H2O (4 °C), in. H2O (20 °C), kPa, cm H2O (4 °C),
 cm H2O (20 °C), bar, mbar, kg/cm², mmHg, in Hg
Technical Data
Measure Accuracy:
Range:  0-24 mA
Resolution:  0.001 mA
Accuracy:  0.02% rdg ± 2 counts
Display
 LCD, 5 digit pressure and current simultaneous
Environmental Specifications
Operating Temperature
 -10ºC to 55ºC
Storage Temperature
 -40ºC to 60ºC
Humidity (Without Condensation)
 95% (10ºC to 30ºC)
 75% (30ºC to 40ºC)
 45% (40ºC to 50ºC)
 35% (50ºC to 55ºC)
Operating Altitude
 3,000 m max
Safety Specifications
Safety
 ATEX II 1G Ex ia IIC T4 compliant
 CSA Certification I.S. Class I,
 Div 1 Groups A-D , T4
Mechanical & General Specifications
Size
 216 mm L x 94 mm W x 66 mm H (with holster)
Weight
 Approx. 992 g (with holster)
Warranty
 Three years, one year for pump
Shock
 1 meter drop test
Vibration
 Random, 2 G, 5-500 Hz
Battery type
 One 9-volt alkaline battery ANSI/NEDA 1604A or IEC 6LR619V
 Battery life: 4 to 20 hours, depending on functions used


Fluke 718Ex

OVERVIEW & SPECIFICATION

The new Fluke 718Ex Intrinsically Safe Pressure Calibrator is a new, powerful intrinsically safe, self contained pressure calibrator for usage in Explosion endangered areas.

The Fluke 718Ex offers:

  • ATEX II 1G Ex ia IIC T4 Compliant.
  • Built-in pressure / vacuum hand pump, with fine adjust vernier and bleed valve.
  • 30, 100, and 300 psi ranges (2, 7, and 20 bar)
  • Pressure measurement to 0.05% of full span, using an internal pressure sensor.
  • Pressure measurement to 200 bar using any of eight intrinsically safe Fluke 700PEx Pressure Modules.
  • Wide range of selectable measurement units for pressure.
  • Current measurement with 0.02% accuracy and 0.001 mA resolution.
  • Pressure switch test function.
  • Min-Max Hold functions.
  • Compact size and weight.
  • Simple, push-button user interface.
  • Rugged and reliable, ideal for field use.
Measurement Accuracy
Pressure
Fluke 718Ex 30G
Range:  -830 mbar to 2 bar (internal sensor)
 Over pressure: 3x FS
Resolution:  0.0001 bar
Accuracy:  0.05% FS
Functions:  Zero, Min, Max, Hold, Damp
 Note: for use with non-corrosive gasses
Fluke 718Ex 100G
Range:  -830 mbar to 7 bar (internal sensor)
 Over pressure: 2x FS
Resolution:  0.001 bar
Accuracy:  0.05% FS
Functions:  Zero, Min, Max, Hold, Damp
 Note: for use with non-corrosive gasses
Fluke 718Ex 300G
Range:  -830 mbar to 20 bar (internal sensor)
 Over pressure: 375 psi, 25 bar
Resolution:  0.0001 bar
Accuracy:  0.05% FS
Functions:  Zero, Min, Max, Hold, Damp
 Note: for use with non-corrosive gasses
Fluke 718Ex series
 via pressure module connector
Range:  29 pressure modules, 2.5 mbar to 700 bar
 Over pressure per pressure module specs
Resolution:  Per pressure module specs
Accuracy:  To 0.025% of full span, per pressure module specs
Functions:  Zero, Min, Max, Hold, Damp
 Note: media compatibility per pressure module specs
Source Pressure, built in pump
Range:  -820 mbar to full scale
Note:  Supported Pressure Units PSI, in. H2O (4 °C), in. H2O (20 °C), kPa, cm H2O (4 °C),
 cm H2O (20 °C), bar, mbar, kg/cm², mmHg, in Hg
Technical Data
Measure Accuracy:
Range:  0-24 mA
Resolution:  0.001 mA
Accuracy:  0.02% rdg ± 2 counts
Display
 LCD, 5 digit pressure and current simultaneous
Environmental Specifications
Operating Temperature
 -10ºC to 55ºC
Storage Temperature
 -40ºC to 60ºC
Humidity (Without Condensation)
 95% (10ºC to 30ºC)
 75% (30ºC to 40ºC)
 45% (40ºC to 50ºC)
 35% (50ºC to 55ºC)
Operating Altitude
 3,000 m max
Safety Specifications
Safety
 ATEX II 1G Ex ia IIC T4 compliant
 CSA Certification I.S. Class I,
 Div 1 Groups A-D , T4
Mechanical & General Specifications
Size
 216 mm L x 94 mm W x 66 mm H (with holster)
Weight
 Approx. 992 g (with holster)
Warranty
 Three years, one year for pump
Shock
 1 meter drop test
Vibration
 Random, 2 G, 5-500 Hz
Battery type
 One 9-volt alkaline battery ANSI/NEDA 1604A or IEC 6LR619V
 Battery life: 4 to 20 hours, depending on functions used