OVERVIEW & SPECIFICATION

The Fluke 810 Vibration Tester is the most advanced troubleshooting tool for mechanical maintenance teams who need an answer now. The unique diagnostic technology helps you quickly identify and prioritize mechanical problems, putting the expertise of a vibration analyst in your hands.

Diagnostic specifications
Standard faults
Unbalance, looseness, misalignment and bearing failures
Analysis for
Motors, fans, blowers, belts and chain drives, gearboxes, couplings, centrifugal pumps, piston pumps, sliding vane pumps, propeller pumps, screw pumps, rotary thread/gear/lobe pumps, piston compressors, centrifugal compressors, screw compressors, closed coupled machines, spindles
Machine rotational speed range
200 rpm to 12000 rpm
Diagnosis details
Plain-text diagnosis, fault severity (slight, moderate, serious, extreme), repair details, cited peaks, spectra
Electrical specifications
Ranging
Automatic
A/D converter
4 channel, 24 bit
Usable bandwidth
2 Hz to 20 kHz
Sampling
51.2 Hz
Digital signal processing functions
Automatically configured anti-alias filter, high-pass filter, decimation, overlapping, windowing, FFT, and averaging
Sampling rate
2.5 kHz to 50 kHz
Dynamic range
128 dB
Signal to noise ratio
100 dB
FFT resolution
800 lines
Spectral windows
Hanning
Frequency units
Hz, orders, cpm
Amplitude units
in/sec, mm/sec, VdB (US), VdB* (Europe)
Non-volatile memory
SD micro memory card, 2 GB internal + user accessible slot for additional storage
General specifications
Dimensions (HxDxW)
18.56 cm x 7.00 cm x 26.72 cm (7.30 in x 2.76 in x 10.52 in)
Weight (with battery)
1.9 kg (4.2 lb)
Display
¼ VGA, 320 × 240 Color (5.7 inch diagonal) TFT LCD with LED backlight
Input/Output Connections
Triaxial sensor connection 4 pin M12 connector
Single axis sensor connection BNC connector
Tachometer Connection Mini DIN 6 pin connector
PC Connection Mini ‘B’ USB (2.0) connector
Battery
Battery type Lithium-ion, 14.8 V, 2.55 Ah
Battery charging time Three hours
Battery discharge time Eight hours (under normal conditions)
AC adapter
Input voltage 100 Vac to 240 Vac
Input frequency 50/60 Hz
Operating system
WinCE 6.0 Core
Language Support
English, French, German, Italian, Japanese, Portuguese, Simplified Chinese, Spanish
Warranty
Three-years
Environmental Specifications
Operating temperature
0 °C to 50 °C (32 °F to 122 °F)
Storage temperature
-20 °C to 60 °C (-4 °F to 140 °F)
Operating humidity
10 % to 95 % RH (non-condensing)
Agency approvals
CHINA RoHS, CSA, CE, C TICK, WEEE
Electromagnetic compatibility
EN 61326-1:2006, EN 61010:1:2001 2nd ed.
Sensor specifications
Sensor type
Accelerometer
Sensitivity
100 mV/g (± 5 %, 25 °C)
Acceleration range
80 g peak
Amplitude nonlinearity
1 %
Frequency response
Z: 2 – 7,000 Hz ± 3dB
X, Y: 2 – 5,000 Hz ± 3dB
Power requirement (IEPE)
18 V dc to 30 V dc, 2 mA to 10 mA
Bias output voltage
12 V dc
Grounding
Case grounded
Sensing element design
PZT ceramic / shear
Case material
316L stainless steel
Mounting
10-32 captive socket head screw, 2-pole rare earth magnet (48 lb pull strength)
Output connector
4-Pin, M12
Mating connector
M12 – F4D
Non-volatile memory
TEDS 1451.4 compatible
Vibration limit
500 g peak
Shock limit
5000 g peak
Electromagnetic sensitivity, equivalent g
100 μg/gauss
Sealing
Hermetic
Temperature range
-50 °C to 120 °C (-58 °F to 248 °F) ± 7 %
Warranty
One-year
Tachometer specifications
Dimensions (DxW)
2.86 cm x 12.19 cm (1.125 in x 4.80 in)
Weight
96 g (3.4 oz) with cable
Power
Powered by 810 Vibration Tester
Detection
Laser Diode Class 2
Range
6.0 to 99,999 rpm
Accuracy
6.0 to 5999.9 rpm: ± 0.01 % and ± 1 digit
5999.9 to 99999 rpm: ± 0.05 % and ± 1 digit
Resolution
0.1 rpm
Effective range
1 cm to 100 cm (0.4 in to 39.27 in)
Response time
1 second (> 60 rpm)
Controls
Measure on/off transparent button
Interface
6 Pin Mini DIN
Cable length
50 cm (19.586 in)
Warranty
One-year
Tachometer accessories
Reflective tape: 1.5 cm x 52.5 cm (0.59 in × 20.67 in)
Viewer PC Software
Minimum hardware requirements
1 GB RAM
Operating system requirements
Windows XP, Vista

 



Fluke 810

OVERVIEW & SPECIFICATION

The Fluke 810 Vibration Tester is the most advanced troubleshooting tool for mechanical maintenance teams who need an answer now. The unique diagnostic technology helps you quickly identify and prioritize mechanical problems, putting the expertise of a vibration analyst in your hands.

Diagnostic specifications
Standard faults
Unbalance, looseness, misalignment and bearing failures
Analysis for
Motors, fans, blowers, belts and chain drives, gearboxes, couplings, centrifugal pumps, piston pumps, sliding vane pumps, propeller pumps, screw pumps, rotary thread/gear/lobe pumps, piston compressors, centrifugal compressors, screw compressors, closed coupled machines, spindles
Machine rotational speed range
200 rpm to 12000 rpm
Diagnosis details
Plain-text diagnosis, fault severity (slight, moderate, serious, extreme), repair details, cited peaks, spectra
Electrical specifications
Ranging
Automatic
A/D converter
4 channel, 24 bit
Usable bandwidth
2 Hz to 20 kHz
Sampling
51.2 Hz
Digital signal processing functions
Automatically configured anti-alias filter, high-pass filter, decimation, overlapping, windowing, FFT, and averaging
Sampling rate
2.5 kHz to 50 kHz
Dynamic range
128 dB
Signal to noise ratio
100 dB
FFT resolution
800 lines
Spectral windows
Hanning
Frequency units
Hz, orders, cpm
Amplitude units
in/sec, mm/sec, VdB (US), VdB* (Europe)
Non-volatile memory
SD micro memory card, 2 GB internal + user accessible slot for additional storage
General specifications
Dimensions (HxDxW)
18.56 cm x 7.00 cm x 26.72 cm (7.30 in x 2.76 in x 10.52 in)
Weight (with battery)
1.9 kg (4.2 lb)
Display
¼ VGA, 320 × 240 Color (5.7 inch diagonal) TFT LCD with LED backlight
Input/Output Connections
Triaxial sensor connection 4 pin M12 connector
Single axis sensor connection BNC connector
Tachometer Connection Mini DIN 6 pin connector
PC Connection Mini ‘B’ USB (2.0) connector
Battery
Battery type Lithium-ion, 14.8 V, 2.55 Ah
Battery charging time Three hours
Battery discharge time Eight hours (under normal conditions)
AC adapter
Input voltage 100 Vac to 240 Vac
Input frequency 50/60 Hz
Operating system
WinCE 6.0 Core
Language Support
English, French, German, Italian, Japanese, Portuguese, Simplified Chinese, Spanish
Warranty
Three-years
Environmental Specifications
Operating temperature
0 °C to 50 °C (32 °F to 122 °F)
Storage temperature
-20 °C to 60 °C (-4 °F to 140 °F)
Operating humidity
10 % to 95 % RH (non-condensing)
Agency approvals
CHINA RoHS, CSA, CE, C TICK, WEEE
Electromagnetic compatibility
EN 61326-1:2006, EN 61010:1:2001 2nd ed.
Sensor specifications
Sensor type
Accelerometer
Sensitivity
100 mV/g (± 5 %, 25 °C)
Acceleration range
80 g peak
Amplitude nonlinearity
1 %
Frequency response
Z: 2 – 7,000 Hz ± 3dB
X, Y: 2 – 5,000 Hz ± 3dB
Power requirement (IEPE)
18 V dc to 30 V dc, 2 mA to 10 mA
Bias output voltage
12 V dc
Grounding
Case grounded
Sensing element design
PZT ceramic / shear
Case material
316L stainless steel
Mounting
10-32 captive socket head screw, 2-pole rare earth magnet (48 lb pull strength)
Output connector
4-Pin, M12
Mating connector
M12 – F4D
Non-volatile memory
TEDS 1451.4 compatible
Vibration limit
500 g peak
Shock limit
5000 g peak
Electromagnetic sensitivity, equivalent g
100 μg/gauss
Sealing
Hermetic
Temperature range
-50 °C to 120 °C (-58 °F to 248 °F) ± 7 %
Warranty
One-year
Tachometer specifications
Dimensions (DxW)
2.86 cm x 12.19 cm (1.125 in x 4.80 in)
Weight
96 g (3.4 oz) with cable
Power
Powered by 810 Vibration Tester
Detection
Laser Diode Class 2
Range
6.0 to 99,999 rpm
Accuracy
6.0 to 5999.9 rpm: ± 0.01 % and ± 1 digit
5999.9 to 99999 rpm: ± 0.05 % and ± 1 digit
Resolution
0.1 rpm
Effective range
1 cm to 100 cm (0.4 in to 39.27 in)
Response time
1 second (> 60 rpm)
Controls
Measure on/off transparent button
Interface
6 Pin Mini DIN
Cable length
50 cm (19.586 in)
Warranty
One-year
Tachometer accessories
Reflective tape: 1.5 cm x 52.5 cm (0.59 in × 20.67 in)
Viewer PC Software
Minimum hardware requirements
1 GB RAM
Operating system requirements
Windows XP, Vista