Measure voltage … without test leads
Measure voltage up to 1000 V ac through the open fork, without test lead contact to live voltage.+ Without opening covers or removing wire nuts. On wires up to AWG 4/0 (120 mm2), carrying as much as 200 A. It will change your job. Safer. Faster. Easier.
![](http://www.fluke.com/NR/rdonlyres/1430178C-63B7-4E9F-999D-999E5A68131A/0/cert1_64x64px.jpg) ![](http://www.fluke.com/NR/rdonlyres/899E56E4-1675-479F-9E2B-4D02FBDE1787/0/cert2_64x64px.jpg) ![](http://www.fluke.com/NR/rdonlyres/476E9A60-7C8C-46F8-AB7E-194CD0813293/0/cert3_64x64px.jpg) ![](http://www.fluke.com/NR/rdonlyres/19F4CDDB-C911-47FA-8EC2-9AFBBE3B7E78/0/cert4_64x64px.jpg) ![](http://www.fluke.com/NR/rdonlyres/2424D2CA-8884-485E-AEB7-0EB17FF7B9E7/0/cert5_64x64px.jpg)
Voltage measurement requires capacitive path to ground, provided through user in most applications. Ground connection via test lead may be required in some situations.
Product Highlights
- FieldSense technology for ac voltage, current and frequency measurement without making electrical contact to live voltage+
- Simultaneous voltage and current display – shows all power supply measurements at a glance for efficient trouble shooting
- 1 to 1000 V ac or dc (T6-1000)
- 0.1 to 200 A ac
- True-rms voltage and current
- Resistance 1 Ω to 100 kΩ
- Frequency measurement 45 Hz to 66 Hz
- Works with wires up to AWG 4/0 (120 mm2) with a 17.8 mm jaw opening
- HOLD button temporarily freezes the reading for easy viewing
- Easy to read display with backlight
- Accepts optional Fluke TPAK Magnetic Meter Hanger for convenient operation
- Standard two-year warranty; extendable to 4 years through product registration within 45 days of purchase*
Measurement Specifications |
Function |
Requires test leads |
Range |
Resolution |
Accuracy[1] |
FieldSense
ac voltage True-rms |
No |
1000 V |
1 V |
± (3 % + 3 counts) 45 Hz – 66 Hz[2][3] |
FieldSense
ac current True-rms |
No |
200.0 A |
0.1 A |
± (3% + 3 counts) 45 Hz – 66 Hz |
FieldSense
frequency (Hz) |
No |
45 Hz – 66 Hz |
1 Hz |
± (1% + 2 counts)[3] |
Volts ac True-rms |
Yes |
1000 V |
1 V |
± (1.5% + 2 counts) 45 Hz – 66 Hz |
Volts dc |
Yes |
1000 V |
1 V |
± (1% + 2 counts) |
Resistance |
Yes |
2000 Ω |
1 Ω |
± (1% + 2 counts) |
Yes |
20.00 kΩ |
0.01 kΩ |
Yes |
100.0 kΩ |
0.1 kΩ |
Safety |
|
1000 V CAT III
600 V CAT IV |
|
|
Accuracy[1]: ± ( [ % of reading] + [number of least significant digits] ). Accuracy is specified for 1 year after calibration, at 18 °C to 28 °C (64 °F to 82 °F) with relative humidity to 90 %. AC measurements are ac-coupled, RMS responding.
Accuracy[2]: Add 3 % without an external ground connection. External ground connection required for user wearing insulated gloves, standing on an insulated ladder, or otherwise insulated from earth ground.
Accuracy[3]: FieldSense is specified from 16 V to 100 % of range. |
General Specifications |
Calibration |
1-year calibration cycle |
Dimensions |
61.1 x 259.3 x 43.8 mm |
Jaw opening |
17.8 mm |
Weight |
0.35 kg (0.78 lb) |
Temperature
Operating:
Storage: |
-10 °C to +50 °C (14 °F to 122 °F)
-30 °C to +60 °C (-22 °F to +140 °F) |
Altitude
Operating:
Storage: |
2,000 m (6,562 feet)
10,000 m (32,808 feet) |
Relative Humidity |
0% to 90%, 5 °C to 30 °C (41 °F to 86 °F)
0% to 75%, 30°C to 40 °C (86 °F to 104 °F)
0% to 45%, 40°C to 50 °C (104 °F to 122 °F) |
Battery Type and Life |
2 x AA (IEC LR6); 360 hours continuous, typical; 200 hours using FieldSense |
Temperature coefficient |
0.1 x (specified accuracy) / °C for <18°C or >28 °C
(< 64.4 °F or > 82.4 °F) |
Safety |
IEC/EN 61010-1: Pollution Degree 2 |
Electromagnetic Environment |
IEC/EN 61326-1: Portable |
|
|
|
|
|
|
|