OVERVIEW & SPECIFICATION

The testo 420 air capture hood for larger air inlets and outlets enables fast and precise compliance with hygiene guidelines and requirements concerning room air quality. It provides reliable support with the calculation of the overall air capture on HVAC systems, for instance in hospitals, office buildings or commercial buildings.
High measuring accuracy at swirl outlets thanks to air capture straightener
Air capture is frequently measured at swirl outlets. Air flows are often incorrectly measured due to the turbulent air at these outlets.
Temperature – NTC
Measuring range -20 to +70 °C
Accuracy ±0.5 °C (0 to +70 °C)

±0.8 °C (-20 to +0 °C)

Resolution 0.1 °C
Reaction time 45 s (t90)
Humidity – Capacitive
Measuring range 0 to 100 %RH
Accuracy ±1.8 %RH + 3 % of mv at +25 °C

(5 to 80 %RH)

Resolution 0.1 %RH
Differential Pressure – Piezoresistive
Measuring range -120 to +120 Pa
Accuracy ±2 % of mv + 0.5 Pa at +22 °C, 1013 hPa
Resolution 0.001 Pa
Reaction time 1 s (t90)
Absolute Pressure
Measuring range 700 to 1100 hPa
Accuracy ±3 hPa
Resolution 0.1 hPa
Reaction time 1 s
Volume flow
Measuring range 40 to 4000 m³/h
Accuracy ±3 % of mv + 12 m³/h at +22 °C

1013 hPa (85 to 3500 m³/h)

Reaction time 1 s (t90)
Resolution 1 m³/h
General technical data
Dimensions 610 x 610 mm (Standard hood)
Operating temperature -5 to +50 °C
EU-/EG-guidelines EU-guideline 2014/30/EU
Warranty 2 years
Battery type Alkali manganese, mignon, type AA
Battery life 40 h
Display size 3.5″
Display function Dot matrix
Display ligthing with illumination
Interface Micro-USB; Bluetooth® 4.0 wireless technology
Memory 2 GB (internal)
Storage temperature -20 to +60 °C
Weight 2900 g


testo-420

OVERVIEW & SPECIFICATION

The testo 420 air capture hood for larger air inlets and outlets enables fast and precise compliance with hygiene guidelines and requirements concerning room air quality. It provides reliable support with the calculation of the overall air capture on HVAC systems, for instance in hospitals, office buildings or commercial buildings.
High measuring accuracy at swirl outlets thanks to air capture straightener
Air capture is frequently measured at swirl outlets. Air flows are often incorrectly measured due to the turbulent air at these outlets.
Temperature – NTC
Measuring range -20 to +70 °C
Accuracy ±0.5 °C (0 to +70 °C)

±0.8 °C (-20 to +0 °C)

Resolution 0.1 °C
Reaction time 45 s (t90)
Humidity – Capacitive
Measuring range 0 to 100 %RH
Accuracy ±1.8 %RH + 3 % of mv at +25 °C

(5 to 80 %RH)

Resolution 0.1 %RH
Differential Pressure – Piezoresistive
Measuring range -120 to +120 Pa
Accuracy ±2 % of mv + 0.5 Pa at +22 °C, 1013 hPa
Resolution 0.001 Pa
Reaction time 1 s (t90)
Absolute Pressure
Measuring range 700 to 1100 hPa
Accuracy ±3 hPa
Resolution 0.1 hPa
Reaction time 1 s
Volume flow
Measuring range 40 to 4000 m³/h
Accuracy ±3 % of mv + 12 m³/h at +22 °C

1013 hPa (85 to 3500 m³/h)

Reaction time 1 s (t90)
Resolution 1 m³/h
General technical data
Dimensions 610 x 610 mm (Standard hood)
Operating temperature -5 to +50 °C
EU-/EG-guidelines EU-guideline 2014/30/EU
Warranty 2 years
Battery type Alkali manganese, mignon, type AA
Battery life 40 h
Display size 3.5″
Display function Dot matrix
Display ligthing with illumination
Interface Micro-USB; Bluetooth® 4.0 wireless technology
Memory 2 GB (internal)
Storage temperature -20 to +60 °C
Weight 2900 g