Fluke-414D/419D/424D on your tool belt and reach beyond the common tape measure – up to 50 meters (165 ft). This professional-grade laser distance meter is fast and easy to use, improving accuracy and reducing measurement errors. You’ll save time and money at every step.
414D
419D
424D
Distance Measurement
Typical Measuring Tolerance[1]
± 2.0 mm [3]
± 1.0 mm [3]
Maximum Measuring Tolerance[2]
± 3.0 mm [3]
± 2.0 mm [3]
Range at Leica target plate GZM26
50 m / 165 ft
80 m / 260 ft
100 m / 330 ft
Typical Range[1]
40 m / 130 ft
80 m / 260 ft
80 m / 260 ft
Range at unfavorable condition[4]
35 m / 115 ft
60 m / 195 ft
60 m / 195 ft
Smallest unit displayed
1 mm / 1/16 in
6 /30 / 60 mm
(10 / 50 / 100 m)
∅ laser point at distances
6 /30 / 60 mm
(10 / 50 / 100 m)
6 /30 / 60 mm
(10 / 50 / 100 m)
Tilt measurement
Measuring tolerance to laser beam[5]
No
No
± 0.2°
Measuring tolerance to housing[5]
No
No
± 0.2°
Range
No
No
360°
General
Laser class
2
Laser type
635 nm, <1 mW
Protection class
IP40
IP54
Automatic laser off
After 90 seconds
Automatic power off
after 180 seconds
Battery life (2 x AAA) 1.5 V NEDA 24A/IEC LR03
Up to 3,000
measurements
Up to 5,000
measurements
Size (H X W X L)
116mm Length
53mm Width
33mm Depth
127mm Length
56mm Width
33mm Depth
127mm Length
56mm Width
33mm Depth
Weight (with batteries)
113 g
153 g
158 g
Temperature range: Storage Operation
-25 °C to +70°C
(-13 °F to +158 °F)0 °C to +40 °C
(32 °F to +104 °F)
-25 °C to +70°C
(-13 °F to +158 °F)-10 °C to +50 °C
(14 °F to +122 °F)
Calibration cycle
Not applicable
Not applicable
Tilt and compass
Maximum altitude
3000 m
3000 m
3000 m
Maximum relative humidity
85% at 20 °F to 120°F
(-7 °C to 50 °C)
85% at 20 °F to 120°F
(-7 °C to 50 °C)
85% at 20 °F to 120°F
(-7 °C to 50 °C)
Safety
IEC Standard No. 61010-1:2001
EN60825-1:2007 (Class II)
EMC
EN 55022:2010
EN 61000-4-3:2010
EN 61000-4-8:2010
[1] Applies for 100 % target reflectivity (white painted wall), low background illumination, 25 °C.
[2] Applies for 10 to 500 % target reflectivity, high background illumination, -10 °C to +50 °C.
[3] Tolerances apply from 0.05 m to 10 m with a confidence level of 95 %. The maximum tolerance may deteriorate to 0.1 mm/m between 10 m to 30 m and to 0.15 mm/m for distances above 30 m.
[4] Applies for 100 % target reflectivity, background illumination between 10’000 lux and 30’000 lux.
[5] After user calibration. Additional angle related deviation of ±0.01° per degree up to ±45° in each quadrant. Applies at room temperature. For the whole operating temperature range the maximum deviation increases by ±0.1°.