The Fluke 437 Series II 400Hz Power Quality and Energy Analyzer is designed specifically for the defense and avionics industries. Capable of measuring up to 400 Hz, the 437 II is a must-have for those working in submarines, aircrafts, and other transport applications.

Applications

  • 400 Hz measurement – capture power quality measurements for avionic and military power systems.
  • PowerWave data capture – capture fast RMS values to see every waveform so you can determine how the voltage, current and frequency values are interacting.
  • Power inverter efficiency – measure both ac power and dc power, in and out, to monitor the efficiency of inverters.
  • Energy monetization – calculate the fiscal cost of energy waste due to poor power quality.
  • Energy assessment– quantify the before and after installation improvements in energy consumption to justify energy saving devices.
  • Frontline troubleshooting – quickly diagnose problems on-screen to get your operation back online.
  • Predictive maintenance – detect and prevent power quality issues before they cause downtime.
  • Long-term analysis – uncover hard-to-find or intermittent issues.
  • Load studies – verify electrical system capacity before adding loads.

 

Product specifications

  Model Measurement range Resolution Accuracy
Volt
Vrms (ac+dc) 434-II 1 V to 1000 V phase to neutral 0.1 V ± 0.5% of nominal voltage****
435-II and 437-II 1 V to 1000 V phase to neutral 0.01 V ± 0.1% of nominal voltage****
Vpk 1 Vpk to 1400 Vpk 1 V 5% of nominal voltage
Voltage Crest Factor (CF) 1.0 > 2.8 0.01 ± 5 %
Vrms½ 434-II 1 V to 1000 V phase to neutral 0.1 V ± 1% of nominal voltage
434-II and 435-II 0.1 V ± 0.2% of nominal voltage
Vfund 434-II 1 V to 1000 V phase to neutral 0.1 V ± 0.5% of nominal voltage
435-II and 437-II 0.1 V ± 0.1% of nominal voltage
Amps (accuracy excluding clamp accuracy)
Amps (ac +dc) i430-Flex 1x 5 A to 6000 A 1 A ± 0.5% ± 5 counts
i430-Flex 10x 0.5 A to 600 A 0.1 A ± 0.5% ± 5 counts
1mV/A 1x 5 A to 2000 A 1A ± 0.5% ± 5 counts
1mV/A 10x 0.5 A A to 200 A (ac only) 0.1 A ± 0.5% ± 5 counts
Apk i430-Flex 8400 Apk 1 Arms ± 5 %
1mV/A 5500 Apk 1 Arms ± 5 %
A Crest Factor (CF) 1 to 10 0.01 ± 5 %
Amps½ i430-Flex 1x 5 A to 6000 A 1 A ± 1% ± 10 counts
i430-Flex 10x 0.5 A to 600 A 0.1 A ± 1% ± 10 counts
1mV/A 1x 5 A to 2000 A 1A ± 1% ± 10 counts
1mV/A 10x 0.5 A A to 200 A (ac only) 0.1 A ± 1% ± 10 counts
Afund i430-Flex 1x 5 A to 6000 A 1 A ± 0.5% ± 5 counts
i430-Flex 10x 0.5 A to 600 A 0.1 A ± 0.5% ± 5 counts
1mV/A 1x 5 A to 2000 A 1A ± 0.5% ± 5 counts
1mV/A 10x 0.5 A A to 200 A (ac only) 0.1 A ± 0.5% ± 5 counts
Hz
Hz Fluke 434 @ 50 Hz nominal 42.50 Hz to 57.50 Hz 0.01 Hz ± 0.01 Hz
Fluke 434 @ 60 Hz nominal 51.00 Hz to 69.00 Hz 0.01 Hz ± 0.01 Hz
Fluke 435/7 @ 50 Hz nominal 42.500 Hz to 57.500 Hz 0.001 Hz ± 0.01 Hz
Fluke 435/7 @ 60 Hz nominal 51.000 Hz to 69.000 Hz 0.001 Hz ± 0.01 Hz
Fluke 437 @ 400 Hz nominal 340.0 Hz to 460.0 Hz 0.1 Hz ± 0.1 Hz
Power
Watts (VA, var) i430-Flex max 6000 MW 0.1 W to 1 MW ± 1% ± 10 counts
1 mV/A max 2000 MW 0.1 W to 1 MW ± 1% ± 10 counts
Power factor (Cos j/DPF) 0 to 1 0.001 ± 0.1% @ nominal load conditions
Energy
kWh (kVAh, kvarh) i430-Flex 10x Depends on clamp scaling and V nominal ± 1% ± 10 counts
Energy loss i430-Flex 10x Depends on clamp scaling and V nominal ± 1% ± 10 counts Excluding line resistance accuracy
Harmonics
Harmonic order (n) DC, 1 to 50 Grouping: Harmonic groups according to IEC 61000-4-7
Inter-harmonic order (n) OFF, 1 to 50 Grouping: Harmonic and Interharmonic subgroups according to IEC 61000-4-7
Volts %f 0.0 % to 100 % 0.1 % ± 0.1% ± n x 0.1 %
%r 0.0 % to 100 % 0.1 % ± 0.1% ± n x 0.4 %
Absolute 0.0 to 1000 V 0.1 V ± 5% *
THD 0.0 % to 100 % 0.1 % ± 2.5 %
Amps %f 0.0 % to 100 % 0.1 % ± 0.1% ± n x 0.1%
%r 0.0 % to 100 % 0.1 % ± 0.1% ± n x 0.4 %
Absolute 0.0 to 600 A 0.1 A ± 5% ± 5 counts
THD 0.0 % to 100 % 0.1 % ± 2.5 %
Watts %f or %r 0.0 % to 100 % 0.1 % ± n x 2%
Absolute Depends on clamp scaling and V nominal ± 5% ± n x 2 % ± 10 counts
THD 0.0 % to 100 % 0.1 % ± 5 %
Phase Angle -360° to +0° ± n x 1°
Flicker
Plt, Pst, Pst(1min) Pinst 0.00 to 20.00 0.01 ± 5 %
Unbalance
Volts % 0.0 % to 20.0 % 0.1 % ± 0.1 %
Amps % 0.0 % to 20.0 % 0.1% ± 1 %
Mains signaling
Threshold levels Threshold, limits and signaling duration is programable for two signaling frequencies
Signaling frequency 60 Hz to 3000 Hz 0.1 Hz
Relative V% 0 % to 100 % 0.10 % ± 0.4 %
Absolute V3s (3 second avg.) 0.0 V to 1000 V 0.1 V ± 5 % of nominal voltage

 

General specifications

Case Design Rugged, shock proof with integrated protective holster Drip and dust proof IP51 according to IEC60529 when used in tilt stand position Shock and vibration Shock 30 g, vibration: 3 g sinusoid, random 0.03 g 2 /Hz according to MIL-PRF-28800F Class 2
Display Brightness: 200 cd/m 2 typ. using power adapter, 90 cd/m 2 typical using battery power Size: 127 mm x 88 mm (153 mm/6.0 in diagonal) LCD Resolution: 320 x 240 pixels Contrast and brightness: user-adjustable, temperature compensated
Memory 8GB SD card (SDHC compliant, FAT32 formatted) standard, upto 32GB optionally Screen save and multiple data memories for storing data including recordings (dependent on memory size)
Real-time clock Time and date stamp for Trend mode, Transient display, System Monitor and event capture

 

Environmental

Operating temperature 0 °C ~ +40 °C; +40 °C ~ +50 °C excl. battery
Storage temperature -20 °C ~ +60 °C
Humidity +10 °C ~ +30 °C: 95% RH non-condensing
+30 °C ~ +40 °C: 75% RH non-condensing
+40 °C ~ +50 °C: 45% RH non-condensing
Maximum operating altitude Up to 2,000 m (6666 ft) for CAT IV 600 V, CAT III 1000 V
Up to 3,000 m (10,000 ft) for CAT III 600 V, CAT II 1000 V
Maximum storage altitude 12 km (40,000 ft)
Electro-Magnetic-Compatibility (EMC) EN 61326 (2005-12) for emission and immunity
Interfaces mini-USB-B, Isolated USB port for PC connectivity SD card slot accessible behind instrument battery
Warranty Three years (parts and labor) on main instrument, one year on accessories


Fluke 437 Series II 400Hz Power Quality and Energy Analyzer

The Fluke 437 Series II 400Hz Power Quality and Energy Analyzer is designed specifically for the defense and avionics industries. Capable of measuring up to 400 Hz, the 437 II is a must-have for those working in submarines, aircrafts, and other transport applications.

Applications

  • 400 Hz measurement – capture power quality measurements for avionic and military power systems.
  • PowerWave data capture – capture fast RMS values to see every waveform so you can determine how the voltage, current and frequency values are interacting.
  • Power inverter efficiency – measure both ac power and dc power, in and out, to monitor the efficiency of inverters.
  • Energy monetization – calculate the fiscal cost of energy waste due to poor power quality.
  • Energy assessment– quantify the before and after installation improvements in energy consumption to justify energy saving devices.
  • Frontline troubleshooting – quickly diagnose problems on-screen to get your operation back online.
  • Predictive maintenance – detect and prevent power quality issues before they cause downtime.
  • Long-term analysis – uncover hard-to-find or intermittent issues.
  • Load studies – verify electrical system capacity before adding loads.

 

Product specifications

  Model Measurement range Resolution Accuracy
Volt
Vrms (ac+dc) 434-II 1 V to 1000 V phase to neutral 0.1 V ± 0.5% of nominal voltage****
435-II and 437-II 1 V to 1000 V phase to neutral 0.01 V ± 0.1% of nominal voltage****
Vpk 1 Vpk to 1400 Vpk 1 V 5% of nominal voltage
Voltage Crest Factor (CF) 1.0 > 2.8 0.01 ± 5 %
Vrms½ 434-II 1 V to 1000 V phase to neutral 0.1 V ± 1% of nominal voltage
434-II and 435-II 0.1 V ± 0.2% of nominal voltage
Vfund 434-II 1 V to 1000 V phase to neutral 0.1 V ± 0.5% of nominal voltage
435-II and 437-II 0.1 V ± 0.1% of nominal voltage
Amps (accuracy excluding clamp accuracy)
Amps (ac +dc) i430-Flex 1x 5 A to 6000 A 1 A ± 0.5% ± 5 counts
i430-Flex 10x 0.5 A to 600 A 0.1 A ± 0.5% ± 5 counts
1mV/A 1x 5 A to 2000 A 1A ± 0.5% ± 5 counts
1mV/A 10x 0.5 A A to 200 A (ac only) 0.1 A ± 0.5% ± 5 counts
Apk i430-Flex 8400 Apk 1 Arms ± 5 %
1mV/A 5500 Apk 1 Arms ± 5 %
A Crest Factor (CF) 1 to 10 0.01 ± 5 %
Amps½ i430-Flex 1x 5 A to 6000 A 1 A ± 1% ± 10 counts
i430-Flex 10x 0.5 A to 600 A 0.1 A ± 1% ± 10 counts
1mV/A 1x 5 A to 2000 A 1A ± 1% ± 10 counts
1mV/A 10x 0.5 A A to 200 A (ac only) 0.1 A ± 1% ± 10 counts
Afund i430-Flex 1x 5 A to 6000 A 1 A ± 0.5% ± 5 counts
i430-Flex 10x 0.5 A to 600 A 0.1 A ± 0.5% ± 5 counts
1mV/A 1x 5 A to 2000 A 1A ± 0.5% ± 5 counts
1mV/A 10x 0.5 A A to 200 A (ac only) 0.1 A ± 0.5% ± 5 counts
Hz
Hz Fluke 434 @ 50 Hz nominal 42.50 Hz to 57.50 Hz 0.01 Hz ± 0.01 Hz
Fluke 434 @ 60 Hz nominal 51.00 Hz to 69.00 Hz 0.01 Hz ± 0.01 Hz
Fluke 435/7 @ 50 Hz nominal 42.500 Hz to 57.500 Hz 0.001 Hz ± 0.01 Hz
Fluke 435/7 @ 60 Hz nominal 51.000 Hz to 69.000 Hz 0.001 Hz ± 0.01 Hz
Fluke 437 @ 400 Hz nominal 340.0 Hz to 460.0 Hz 0.1 Hz ± 0.1 Hz
Power
Watts (VA, var) i430-Flex max 6000 MW 0.1 W to 1 MW ± 1% ± 10 counts
1 mV/A max 2000 MW 0.1 W to 1 MW ± 1% ± 10 counts
Power factor (Cos j/DPF) 0 to 1 0.001 ± 0.1% @ nominal load conditions
Energy
kWh (kVAh, kvarh) i430-Flex 10x Depends on clamp scaling and V nominal ± 1% ± 10 counts
Energy loss i430-Flex 10x Depends on clamp scaling and V nominal ± 1% ± 10 counts Excluding line resistance accuracy
Harmonics
Harmonic order (n) DC, 1 to 50 Grouping: Harmonic groups according to IEC 61000-4-7
Inter-harmonic order (n) OFF, 1 to 50 Grouping: Harmonic and Interharmonic subgroups according to IEC 61000-4-7
Volts %f 0.0 % to 100 % 0.1 % ± 0.1% ± n x 0.1 %
%r 0.0 % to 100 % 0.1 % ± 0.1% ± n x 0.4 %
Absolute 0.0 to 1000 V 0.1 V ± 5% *
THD 0.0 % to 100 % 0.1 % ± 2.5 %
Amps %f 0.0 % to 100 % 0.1 % ± 0.1% ± n x 0.1%
%r 0.0 % to 100 % 0.1 % ± 0.1% ± n x 0.4 %
Absolute 0.0 to 600 A 0.1 A ± 5% ± 5 counts
THD 0.0 % to 100 % 0.1 % ± 2.5 %
Watts %f or %r 0.0 % to 100 % 0.1 % ± n x 2%
Absolute Depends on clamp scaling and V nominal ± 5% ± n x 2 % ± 10 counts
THD 0.0 % to 100 % 0.1 % ± 5 %
Phase Angle -360° to +0° ± n x 1°
Flicker
Plt, Pst, Pst(1min) Pinst 0.00 to 20.00 0.01 ± 5 %
Unbalance
Volts % 0.0 % to 20.0 % 0.1 % ± 0.1 %
Amps % 0.0 % to 20.0 % 0.1% ± 1 %
Mains signaling
Threshold levels Threshold, limits and signaling duration is programable for two signaling frequencies
Signaling frequency 60 Hz to 3000 Hz 0.1 Hz
Relative V% 0 % to 100 % 0.10 % ± 0.4 %
Absolute V3s (3 second avg.) 0.0 V to 1000 V 0.1 V ± 5 % of nominal voltage

 

General specifications

Case Design Rugged, shock proof with integrated protective holster Drip and dust proof IP51 according to IEC60529 when used in tilt stand position Shock and vibration Shock 30 g, vibration: 3 g sinusoid, random 0.03 g 2 /Hz according to MIL-PRF-28800F Class 2
Display Brightness: 200 cd/m 2 typ. using power adapter, 90 cd/m 2 typical using battery power Size: 127 mm x 88 mm (153 mm/6.0 in diagonal) LCD Resolution: 320 x 240 pixels Contrast and brightness: user-adjustable, temperature compensated
Memory 8GB SD card (SDHC compliant, FAT32 formatted) standard, upto 32GB optionally Screen save and multiple data memories for storing data including recordings (dependent on memory size)
Real-time clock Time and date stamp for Trend mode, Transient display, System Monitor and event capture

 

Environmental

Operating temperature 0 °C ~ +40 °C; +40 °C ~ +50 °C excl. battery
Storage temperature -20 °C ~ +60 °C
Humidity +10 °C ~ +30 °C: 95% RH non-condensing
+30 °C ~ +40 °C: 75% RH non-condensing
+40 °C ~ +50 °C: 45% RH non-condensing
Maximum operating altitude Up to 2,000 m (6666 ft) for CAT IV 600 V, CAT III 1000 V
Up to 3,000 m (10,000 ft) for CAT III 600 V, CAT II 1000 V
Maximum storage altitude 12 km (40,000 ft)
Electro-Magnetic-Compatibility (EMC) EN 61326 (2005-12) for emission and immunity
Interfaces mini-USB-B, Isolated USB port for PC connectivity SD card slot accessible behind instrument battery
Warranty Three years (parts and labor) on main instrument, one year on accessories